Resources
Standard Operating Procedures

SOP Home    Printable Version

Rapid Intervention Team Checklist

Size-Up

  • Building Dimensions (length x width x height)
  • Building Occupancy
  • Building Construction Type
    • Wood frame
    • Ordinary
    • Fire resistive
    • Heavy Timber
  • Noncombustible
  • Placement of windows, doors, fire escapes, porches, and so on.
  • Potential danger of high security doors, barred windows, building modifications.

Tactics

  • Offensive, defensive, defensive-to-offensive (transitional)
  • Command operations
    • Check tactics sheet or board
    • Check accountability
    • Communication/Incident Commanders
  • Ladder and truck operations
  • Fire ground time vs. progress

Equipment

  • Acquire and stage equipment
    Required Equipment Suggested Equipment
    Full PPE, SCBA donned and face pieces ready to be donned Additional radios
    Portable head lamps
    RIT Bag Portable fire extinguishers
    Hose line and secondary water supply (evaluate availability, secure own line) Specialty nozzles such as piercing nozzles and/or distributor nozzles
    2 Portable Radios (include 1 for victim) Ground ladders
    Saws – wood, concrete, metal
    Flathead axe and Halligan tool
    150’ guide rope
    Thermal Imaging Camera
    Additional SCBA

Other Considerations

  • Check with Rehab Officer on condition of firefighters
  • Check with Safety Officer to compare information
  • Relocate or add another RIT; request specialized resources to support RIT
  • Potential collapse and collapse area
  • EMS for the RIT

 